This guide connects the disciplines; it does not replace the specialist references. The committee standards own the classes and requirements you certify against, the OEM documentation governs the build once a platform is chosen, the institutions and analysts produce the measurements and forecasts the register cites. For every entry below: what it is authoritative for, and the moment to leave this site and open it. Access labels as checked 2026-09-05; paid does not mean avoidable.

Thermal envelopes and cooling

The committee references own the environmental classes and the liquid-cooling interface definitions. Use them for the numbers you will write into a specification; use Part 5 for how those numbers interact with the rest of the machine.

ASHRAE

Authoritative for: Air (A1–A4, H1) and facility-water (W17–W45+) environmental classes, liquid-cooling guidelines, the fourteen-book Datacom series as an updated online reference — about $33/year.

Reach for it when: Any inlet, supply-water or humidity limit you intend to put in a design basis or a contract.

What this guide adds: How a class choice moves free-cooling hours, heat reuse, transient ride-through and rack qualification at the same time.

Complements Part 5 · Part 13 · Part 15
ASHRAE · PNNL · NEMA (June 2026)

Authoritative for: Expert-authored, peer-reviewed guidance across siting, integrated design, efficiency, grid interaction, resilience, commissioning, operations and retrofit — the closest free lifecycle reference to this guide.

Reach for it when: A reviewed statement of practice you can cite to an owner or authority; a second opinion on any Part 3–5, 13 or 15 recommendation here.

What this guide adds: Silicon, networking, storage, software and finance, and the decision-and-consequence framing across all of them.

Complements Part 3 · Part 4 · Part 5 · Part 13 · Part 15
Open Compute Project

Authoritative for: Cold-plate development and qualification methods, coolant requirements, ORv3 / Open Rack HPR / ORW rack and power-shelf specifications with drawings and contributor discussion.

Reach for it when: The actual interface specification a rack, manifold, quick-disconnect or power shelf must meet.

Complements Part 4 · Part 5 · Part 7

Facility requirements, resilience and certification

These documents are normative. This guide explains why a requirement matters to an AI workload and where the Tier label stops describing the fault behaviour you actually get; it does not replace the text you certify against.

Uptime Institute

Authoritative for: Tier topology and operational sustainability definitions, the annual global survey and outage analysis, and a 2026 AI-facility paper series (design review, vendor evaluation, construction, L4/L5 commissioning, operations).

Reach for it when: Any statement about Tier III/IV, concurrent maintainability or fault tolerance you intend to rely on; survey PUE and outage benchmarks.

Complements Part 0 · Part 12 · Part 13 · Part 14
ANSI/TIA-942-CPaid standard
Telecommunications Industry Association (2024)

Authoritative for: Normative site, architectural, electrical, mechanical, telecom and security requirements by rating level, with an audit and certification ecosystem.

Reach for it when: A contractual facility specification and its conformity path.

Complements Part 6 · Part 8 · Part 11 · Part 12
BICSI (2024 editions)

Authoritative for: Consensus best practice for data-center design and for operations and maintenance, with training and the DCDC credential behind it.

Reach for it when: Detailed design and operating practice in a form an AHJ or insurer recognises.

Complements Part 6 · Part 13 · Part 14
ISO/IEC · CENELEC

Authoritative for: Facility infrastructure classes, availability, physical security and energy-efficiency enablement requirements used across Europe and internationally; EN 50600-4 defines the KPIs (PUE, WUE, ERF, REF) EU reporting relies on.

Reach for it when: EU or international project requirements and the exact KPI definitions behind the EED reporting obligation.

Complements Part 6 · Part 12 · Part 15

Reference designs and platform documentation

Vendor material is authoritative about the vendor's own product and nothing else. The guide compares across vendors on fixed axes; when you have chosen one, its documentation governs the build.

Schneider Electric

Authoritative for: Engineered facility reference designs for AI halls (RD100, RD48 and successors) and a broad catalog of facility trade-off calculators: build vs colo, cooling architecture, economizer PUE by location, UPS economics, distribution efficiency.

Reach for it when: A bounded, engineered configuration to start from, and a calculator that matches the exact architectural fork you are weighing.

What this guide adds: Vendor-neutral comparison, the workload and economics context, and the register's dated provenance.

Complements Part 4 · Part 5 · Part 6
Vertiv

Authoritative for: Configured power, cooling and rack reference designs for named accelerator generations (GB300-class and beyond).

Reach for it when: The physical-infrastructure bill of materials for a named platform.

Complements Part 4 · Part 5
Eaton

Authoritative for: Electrical distribution, grid-interaction and modular power engineering material for high-density AI loads.

Reach for it when: Electrical product choices and the engineering behind them; separate the engineering papers from the marketing.

Complements Part 4
NVIDIA

Authoritative for: Rack, network, storage and management integration for a named generation; the executable basis for building and accepting an NVIDIA cluster.

Reach for it when: The supported topology, BOM and acceptance requirements once the platform is NVIDIA.

Complements Part 7 · Part 8 · Part 9 · Part 13
AMD

Authoritative for: Cluster design, networking with multiple fabric partners, BOMs, acceptance guidance and the facility interface for MI3xx platforms.

Reach for it when: The supported implementation once the platform is AMD; the counterpart to the SuperPOD guides.

Complements Part 7 · Part 8 · Part 13

Networking and fabrics

Part 8 is a map. These are the territory: firsthand production accounts, a peer-reviewed textbook, and the consortium specifications.

Pearson / Cisco Press (2026) — Subramaniam, Styszynski, Tambakuwala; technical reviewer credited

Authoritative for: Structured, vendor-agnostic AI networking education — scale-up and scale-out fabrics, transports, congestion control, optics, operations — with worked material and review questions.

Reach for it when: Learning AI networking properly, or checking Part 8 against a peer-reviewed treatment.

What this guide adds: The links from fabric decisions to cooling, power, procurement, commissioning and cost.

Complements Part 8
Meta

Authoritative for: A firsthand account of two 24k-GPU clusters, one RoCE and one InfiniBand, both tuned to equivalent performance on GenAI workloads — the primary evidence against any universal transport ranking.

Reach for it when: Whether Ethernet can carry your training workload, and what the tuning actually involved.

Complements Part 8 · Part 10 · Part 14
UEC

Authoritative for: The Ultra Ethernet transport and its profiles as they are actually specified, not as summarised.

Reach for it when: Protocol-level detail behind the transport comparison in Chapter 8.4.

Complements Part 8

Energy, grid and flexibility

For demand forecasts, interconnection data and flexibility programs, go to the institutions that produce them. Part 3, 4 and 15 explain what they mean for a specific site.

International Energy Agency (2025 report; 2026 follow-up)

Authoritative for: Global data-center electricity demand scenarios, supply implications and methodology; the reference forecast most policy discussion cites.

Reach for it when: Demand-growth numbers you will be asked to defend; scenario ranges rather than a single trajectory.

Complements Part 3 · Part 15 · Part 16
Lawrence Berkeley National Laboratory

Authoritative for: Energy assessment tools, the US data-center energy report, and the annual Queued Up interconnection-queue dataset the guide's queue figures come from.

Reach for it when: The primary queue statistics and the methodology caveats that go with them.

Complements Part 3 · Part 15
EPRI DCFlexFree + paid tiers
Electric Power Research Institute

Authoritative for: Applied research and utility demonstrations of data-center load flexibility, the utility-side view of curtailable interconnection.

Reach for it when: Turning a flexibility idea into a program a utility will recognise.

Complements Part 3 · Part 4 · Part 15
Sijbrandij Foundation

Authoritative for: A phased power co-development framework and a coalition directory for getting large loads energized faster.

Reach for it when: A structured process for the utility and generation conversations in Part 3.

Complements Part 3

Economics, benchmarks and market data

The guide's calculators are screening tools. These are the measured or modelled sources you underwrite against.

SemiAnalysis

Authoritative for: Original supply-chain (CoWoS, HBM), rack-teardown and fabric-economics research; InferenceX serving benchmarks by model, stack, precision and SLO; ClusterMAX GPU-cloud ratings. Institutional TCO models are licensed separately.

Reach for it when: Procurement or investment-grade economics, and measured serving envelopes instead of the guide's illustrative throughput constants.

What this guide adds: A common vocabulary across facilities and finance, and the register's separation of what is measured from what is modelled. About a tenth of the register's referenced claims cite SemiAnalysis — treat it as one evidentiary source, not a cross-check of itself.

Complements Part 1 · Part 7 · Part 8 · Part 16
MLCommons

Authoritative for: Governed, reproducible performance (and optional power) measurements with rules, metadata and code links.

Reach for it when: Comparing accelerators within a benchmark's bounds before believing any vendor ratio, including the ones quoted here.

Complements Part 7 · Part 10
Microsoft Research · UT Austin (2026)

Authoritative for: An analytical model that treats hardware refresh as an optimisation variable across build, refresh and inference operations.

Reach for it when: Refresh and lifecycle economics beyond the fixed-exit-multiple screen in the project-finance calculator.

Complements Part 1 · Part 14 · Part 16
JLL · CBRE

Authoritative for: Regional vacancy, pricing, pipeline and lead-time conditions by market, published on a cadence.

Reach for it when: Market-specific availability and price before a siting decision; the guide's regional pages summarise, these are the source.

Complements Part 1 · Part 2 · Part 3

Whole-system reasoning and learning

If you want to understand why the machine behaves the way it does rather than what to buy, start here.

Barroso, Hölzle, Ranganathan — Google (2018)

Authoritative for: The original warehouse-scale-computer argument: co-design, cost models, failure handling and energy proportionality, from the people who ran it.

Reach for it when: Enduring architecture and economics reasoning; the component numbers are dated, the reasoning is not.

Complements Part 0 · Part 1 · Part 12 · Part 14
Google DeepMind authors (2025, revised online)

Authoritative for: Systems mathematics of training and inference: arithmetic intensity, parallelism, rooflines, KV-cache and batching, with derivations and exercises (TPU-centred, GPUs included).

Reach for it when: Any time the guide asserts a bandwidth-bound or compute-bound regime and you want the derivation.

Complements Part 1 · Part 7 · Part 8 · Part 9 · Part 10

Following the field

The numbers here move monthly. These are the original-reporting sources the register is checked against between publishes.

Data Center DynamicsFree + paid tiers
DCD

Authoritative for: Daily project, facility, power and market reporting; DCD Academy courses.

Reach for it when: What happened this week; the register lags it by design.

Complements Part 2 · Part 3 · Part 16
Data Center RichnessFree + paid tiers
Substack newsletter

Authoritative for: Named-analyst commentary on facilities, investment and the operators building them.

Reach for it when: Perspective on the deals and developers behind the capacity numbers.

Complements Part 1 · Part 2 · Part 16

Missing something that belongs here? Tell us through the contact form. The bibliography behind individual figures lives on the register; Appendix E maps the learning and community landscape in more depth.