The Definitive Guide toAI Data Centers
Ask the GuideAboutAccount
Guide › Numbers register › Claim

NVIDIA DGX SuperPOD with DGX Vera Rubin NVL72: Enhanced storage tier per scalable unit of 8 systems (576 GPUs), aggregate read / write

280 / 140 GB/srecommendation

Value kindrecommendation — Recommendations are design guidance, not measured facts; validate them against the project boundary conditions.
ScopeNVIDIA reference storage guideline, not a measured result or a per-GPU floor. The Standard tier is 90 / 45 GB/s per SU; at four SUs Enhanced is 1,120 / 560 GB/s and Standard 360 / 180. Enhanced read works out to about 0.49 GB/s per GPU, the same as NVIDIA's DGX B300 Ethernet reference architecture. Large vision datasets (over 30 TB) call for 4 GB/s per GPU read in all three NVIDIA reference architectures.
As of2026-09
SourceNVIDIA DGX SuperPOD Reference Architecture featuring DGX Vera Rubin NVL72 (storage guidelines, Table 6) · Table 6: single-SU aggregate read 90 / 280 GB/s and write 45 / 140 GB/s (Standard / Enhanced)
Reviewchecking…review by 2027-03-15 · standard cadence
Recorded changeslast 2026-10-16
Claim idper-scalable-unit-read-write-dgx-vera-rubin-nvl72-superpod

Where the guide uses it