Ethernet payload one fiber pair carries in each direction when an OIF 800ZR line system fills all 32 of its 150 GHz C-band channels

~25.6 Tb/s each wayderived

Value kindderived — Derived values are guide calculations; their result is only as fixed as the stated inputs, scope, and method.
ScopeThe 800ZR channel plan (single-span, 80-120 km amplified DWDM). Ethernet client rate, before any protocol overhead above Ethernet. ZR+ or performance modems and C+L line systems give different per-pair figures; use your line-system vendor's channel plan.
CaveatA full-fill ceiling from the standard's channel plan, not a measured link; real systems may light fewer channels.
As of2024-10-08
SourceOIF-800ZR-01.0 Implementation Agreement for 800ZR Coherent Interfaces (2024-10-08); guide multiplication · Section 8.1 and Table 30: 32 channels at 150 GHz spacing, 191.375-196.025 THz; section 9: 800GE client per carrier. 32 x 800 Gb/s = 25.6 Tb/s per fiber direction
Derivation32 normative channels x 800GE client = 25.6 Tb/s per direction of a fiber pair
Reviewchecking…review by 2027-10-19 · standard cadence
Recorded changeslast 2026-10-19
Claim iddwdm-payload-per-fiber-pair-800zr-c-band